Friday 5 December 2014

VPC+ configuration example

Below is the VPC+ configuration example.

VPC+ is configured between N5k-1 and N5k-2 where fabric path is configured on the VPC peer-link. We assume that Teaming is properly configured on the server end and hence only switch side configuration is demonstrated here.





N7K-1:-

Install feature-set fabricpath  //--<<<< It must be executed in Default or Admin VDC //
feature-set fabricpath
feature lacp

fabricpath switch-id 71  //--<< To configure Static switch-id otherwise it will be dynamically assigned//

vlan 100
  mode fabricpath

interface Ethernet1/1
  switchport mode fabricpath

interface Ethernet1/3
  switchport mode fabricpath

interface Ethernet1/4
  switchport mode fabricpath


N7K-2 :-

Install feature-set fabricpath
feature-set fabricpath
feature lacp

fabricpath switch-id 72

vlan 100
  mode fabricpath

interface Ethernet1/1
  switchport mode fabricpath

interface Ethernet1/3
  switchport mode fabricpath

interface Ethernet1/4
  switchport mode fabricpath


N5K-1 :-

Install feature-set fabricpath
feature-set fabricpath
feature Lacp
feature vpc

fabricpath switch-id 51

vpc domain 100
 peer-keepalive destination 10.1.1.52
  fabricpath switch-id 55  //----<<<<<<<<<<<< Must be configured for VPC+ //

vlan 100
  mode fabricpath

interface Ethernet1/1
  Channel-group 1 mode active
  switchport mode fabricpath

interface Ethernet1/2
  Channel-group 1 mode active
  switchport mode fabricpath

interface port-channel1
  switchport mode fabricpath
  VPC peer-link

interface Ethernet1/3
  switchport mode fabricpath

interface Ethernet1/4
  switchport mode fabricpath

interface Ethernet1/5
Channel-group 2000 mode active
  switchport mode trunk

int po2000
switchport mode trunk
vpc 2000
no shut

N5K-2 :-

install feature-set fabricpath
feature-set fabricpath
feature lacp
feature vpc

fabricpath switch-id 52

vlan 100
mode fabricpath

vpc domain 100
 peer-keepalive destination 10.1.1.51
  fabricpath switch-id 55

Note:- If you missed to configure sub switch-id under VPC domain then VPC peer-link will remain down.

interface Ethernet1/1
Channel-group 1 mode active
 switchport mode fabricpath

interface Ethernet1/2
Channel-group 1 mode active
switchport mode fabricpath

interface port-channel1
  switchport mode fabricpath
  VPC peer-link

interface Ethernet1/3
switchport mode fabricpath

interface Ethernet1/4
  switchport mode fabricpath

interface Ethernet1/5
 Channel-group 2000 mode active
  switchport mode trunk

int po2000
switchport mode trunk
vpc 2000
no shut


Verification:-  

1. Show fabricpath switch-id

N7K-1# show fabricpath switch-id
                        FABRICPATH SWITCH-ID TABLE
Legend: '*' - this system
=========================================================================
SWITCH-ID      SYSTEM-ID       FLAGS         STATE    STATIC  EMULATED
----------+----------------+------------+-----------+--------------------
51          0005.73bd.fabc    Primary     Confirmed     Yes     No
52          0005.73bf.337c    Primary     Confirmed     Yes     No
55          0005.73bd.fabc    Primary     Confirmed     No      Yes
55          0005.73bf.337c    Primary     Confirmed     No      Yes
*71          0026.980d.4143    Primary     Confirmed    Yes     No
72          0026.980d.3c43    Primary     Confirmed     Yes     No


2. Show fabricpath isis adjacency


N7K-1# show fabricpath isis adjacency
Fabricpath IS-IS domain: default Fabricpath IS-IS adjacency database:
System ID       SNPA            Level  State  Hold Time  Interface
N5K-1        N/A             1      UP     00:00:28   Ethernet1/3
N5K-2        N/A             1      UP     00:00:26   Ethernet1/4
N7K-2         N/A             1      UP     00:00:28   Ethernet1/1


3. Show vpc brief


N5K -2(config-if)# show vpc brief
Legend:
                (*) - local vPC is down, forwarding via vPC peer-link

vPC domain id                   : 100
vPC+ switch id                  : 55
Peer status                     : peer adjacency formed ok
vPC keep-alive status           : peer is alive
vPC fabricpath status           : peer is reachable through fabricpath---<<<<<<
Configuration consistency status: success
Per-vlan consistency status     : success
Type-2 consistency status       : success
vPC role                        : secondary
Number of vPCs configured       : 1
Peer Gateway                    : Disabled
Dual-active excluded VLANs      : -
Graceful Consistency Check      : Enabled

vPC Peer-link status
---------------------------------------------------------------------
id   Port   Status Active vlans
--   ----   ------ --------------------------------------------------
1    Po1    up     100

vPC status
---------------------------------------------------------------------------
id     Port        Status Consistency Reason       Active vlans vPC+ Attrib
--     ----------  ------ ----------- ------       ------------ -----------
2000     Po2000        up     success     success      100          DF: Partial




4 comments:

  1. explanation done in a very simple manner . great . appreciate for the same

    ReplyDelete
  2. Very good explanation. Thanks a lot for sharing the knowledge.

    ReplyDelete